True Double-conversion Three Phases Online UPS power supply for Home

Model: Double-conversion Three Phases Online UPS Phase: 3phase in/1 Phase Out & 3phase in/3 Phases Out Capacity: 1kva~10kva Wave Type: Pure Sine Wave Brand: ROYCE ENERGY or OEM
The three-phase online UPS power supply guarantees proactive component replacement by offering early-warning fault diagnosis. Its small footprint conserves precious real estate, its fault-tolerant design simplifies installation and maintenance, and its up to 93% efficiency makes utility bills predictable.
For edge, small, and medium data centers as well as important infrastructure in commercial and industrial buildings, a three-phase online ups power supply offers optimal performance. Its fault-tolerant architecture, high-density technology, N+1 redundancy, and compact design minimize total cost of ownership while maximizing availability, operating efficiency, and essential load protection.
Features of Three Phases Online UPS power supply
Real dual conversion
High performance is guaranteed by DSP technology
Output power factor 1 and active PFC; frequency converter mode for 50 Hz and 60 Hz
ECO energy-saving mode and EPO (Emergency power off) function Compatible with generators; and numerous connections via SNMP, USB, and RS-232.
The long-run model's adjustable battery numbers with mark (L*), Optional maintenance bypass, parallel operation, optional isolation transformer (noise rejection mode), and power walk-in function are all features of this 3-stage extensible charging design.
Specifications of Three Phases Online UPS power supply
MODEL | 10K (L)* | 15K(L) | 20K (L)* | 30K (L)* | 40K (L) | 60KL | 80KL | |||
PHASE | 3Ph in/ 3Ph out or 3Ph in 1Ph out | 3-phase in / 3-phase out | ||||||||
CAPACITY | 10KVA /10KW | 15KVA /15KW | 20KVA /20KW | 30KVA /30KW | 40KV /40KW | 60KVA /60KW | 80KVA /80KW | |||
PARALLEL CAPABILITY | up to 4 units in parallel | up to 6 units in parallel | ||||||||
INPUT | ||||||||||
Nominal Voltage | 3X400Vac (3Ph+N) /230Vac(1Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | ||||||||
Voltage Range | 110-300 VAC @ 50% load 176-276 VAC @ 100% load |
-30% ~ +20% | ||||||||
Frequency Range | 46~54 Hz or 56~64Hz | 40~70 Hz | ||||||||
Power Factor | ≧ 0.99 @ 100% Load | |||||||||
Harmonic Distortion (THDi) | < 4% at full linear load | |||||||||
OUTPUT | ||||||||||
Output Voltage | 3X380/400/415Vac (3Ph+N) or 208/220/230/240 VAC (1Ph+N) | 3 x 360*/380/400/415 VAC (3Ph+N) | ||||||||
AC Voltage Regulation (Batt. Mode) | ± 1% | |||||||||
Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | |||||||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50/60 Hz ± 1% | ||||||||
Current Crest Ratio | 3:1 (max.) | |||||||||
Harmonic Distortion | ≦ 2% THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | |||||||||
Transfer Time |
AC Mode to Batt. Mode | Zero | ||||||||
Inverter to Bypass | Zero | |||||||||
Waveform (Batt. Mode) | Pure Sine wave | |||||||||
Overload Capability |
AC Mode | 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately | ||||||||
Battery Mode | 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately | |||||||||
BYPASS | ||||||||||
Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) | |||||||||
Voltage Range | -30% ~ +20% (Adjustable) | |||||||||
Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | |||||||||
Overload Capability | > 130% 1 minute (default) ; continuously working until breaker protection (optional) | |||||||||
EFFICIENCY | ||||||||||
AC Mode | 95.5% | 96.0% | ||||||||
ECO Mode | 98.5% | 99.0% | ||||||||
Battery Mode | 94.5% | 96.0% | ||||||||
BATTERY | ||||||||||
Standard Model |
Battery Type | 12V Lead Acid | 12V Lead Acid | 12 V/7 Ah | 12 V/9 Ah | N/A | ||||
Numbers | (10+10) PCS | (16+16) PCS | (16+16) pcs x 2 strings | |||||||
Typical Recharge Time | 4 hours recover to 90% capacity | 9 hours recover to 90% capacity | ||||||||
Charging Current (max.) | 2A (Adjustable) | 1A ~ 12A | 1A ~ 16 A (Adjustable) | |||||||
Charging Voltage | +/-13.65V*N (N = 10) | +/-13.65V*N (N = 16~20) | +/-218 VDC ± 10% | |||||||
Long-run Model |
Battery Type | Depending on the applications | ||||||||
Numbers | 20PCS | 32PCS | +/-16 pcs ~ +/- 20 pcs (Adjustable) | |||||||
Charging Current (max.) | 1A/2A/3A/4A/5A/6A/7A/8A/9A/10A/11A/12A (Adjustable)12A maximum | 1A ~ 12A (Adjustable) | 1A~16 A (Adjustable) | 2A~24 A (Adjustable) | 2A~32A(Adjustable) | |||||
Charging Voltage | +/-136.5VDC±10% | +/-13.65V x N (N=16~20) | ||||||||
INDICATORS | ||||||||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |||||||||
PHYSICAL | ||||||||||
Standard Model |
Dimension,DxWxH (mm) | 630 x 250 x 826 | 815 x 300 x 1000 | N/A | ||||||
Net Weight (kgs) | 103 | 139 | 225 | 250 | ||||||
Long-run Model |
Dimension,DxWxH (mm) | 630 x 250 x 826 | 815 x 300 x 1000 | 790 x 360 x 1010 | ||||||
Net Weight (kgs) | 36 | 43 | 60 | 67 | 108 | 113 | ||||
ENVIRONMENT | ||||||||||
Operation Temperature | 0-40°C | |||||||||
Operation Humidity | < 95% and non-condensing | |||||||||
Altitude** | 0 ~ 1500m at full load | |||||||||
Noise Level | Less than 60 dB@1 Meter | Less than 65 dB @1 Meter | Less than 63 dB @1 Meter | Less than 65 dB @1 Meter | ||||||
MANAGEMENT | ||||||||||
Smart RS-232 / USB | Supports Windows® Family, Linux and MAC | |||||||||
Optional SNMP | Power management from SNMP manager and web browser |
note: (L* mark means Long backup model)