True Double-conversion Three Phases Online UPS power supply for Home

  • True Double-conversion Three Phases Online UPS power supply for Home
True Double-conversion Three Phases Online UPS power supply for Home

Model: Double-conversion Three Phases Online UPS Phase: 3phase in/1 Phase Out & 3phase in/3 Phases Out Capacity: 1kva~10kva Wave Type: Pure Sine Wave Brand: ROYCE ENERGY or OEM

The three-phase online UPS power supply guarantees proactive component replacement by offering early-warning fault diagnosis. Its small footprint conserves precious real estate, its fault-tolerant design simplifies installation and maintenance, and its up to 93% efficiency makes utility bills predictable.

For edge, small, and medium data centers as well as important infrastructure in commercial and industrial buildings, a three-phase online ups power supply offers optimal performance. Its fault-tolerant architecture, high-density technology, N+1 redundancy, and compact design minimize total cost of ownership while maximizing availability, operating efficiency, and essential load protection.

 

Features of Three Phases Online UPS power supply

⚫ Real dual conversion
⚫ High performance is guaranteed by DSP technology
⚫ Output power factor 1 and active PFC; frequency converter mode for 50 Hz and 60 Hz
⚫ ECO energy-saving mode and EPO (Emergency power off) function Compatible with generators; and numerous connections via SNMP, USB, and RS-232.
⚫ The long-run model's adjustable battery numbers with mark (L*), Optional maintenance bypass, parallel operation, optional isolation transformer (noise rejection mode), and power walk-in function are all features of this 3-stage extensible charging design.

Specifications of Three Phases Online UPS power supply

MODEL 10K (L)* 15K(L) 20K (L)* 30K (L)* 40K (L) 60KL 80KL
PHASE 3Ph in/ 3Ph out or 3Ph in 1Ph out  3-phase in / 3-phase out
CAPACITY 10KVA /10KW 15KVA /15KW 20KVA /20KW 30KVA /30KW 40KV /40KW 60KVA /60KW 80KVA /80KW
PARALLEL CAPABILITY up to 4 units in parallel up to 6 units in parallel
INPUT
Nominal Voltage 3X400Vac (3Ph+N) /230Vac(1Ph+N) 3 x 380/400/415 VAC (3Ph+N)
Voltage Range 110-300 VAC @ 50% load
176-276 VAC @ 100% load
-30% ~ +20%
Frequency Range 46~54 Hz or 56~64Hz 40~70 Hz
Power Factor ≧ 0.99 @ 100% Load
Harmonic Distortion (THDi) < 4% at full linear load
OUTPUT
Output Voltage 3X380/400/415Vac (3Ph+N) or 208/220/230/240 VAC (1Ph+N) 3 x 360*/380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50/60 Hz ± 1%
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦ 2% THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Transfer
Time
AC Mode to Batt. Mode Zero
Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sine wave
Overload
Capability
AC Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately
Battery Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately
BYPASS
Nominal Voltage 3 x 380/400/415 VAC (3Ph+N)
Voltage Range -30% ~ +20% (Adjustable)
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Overload Capability > 130% 1 minute (default) ; continuously working until breaker protection (optional)
EFFICIENCY
AC Mode 95.5% 96.0%
ECO Mode 98.5% 99.0%
Battery Mode 94.5% 96.0%
BATTERY
Standard
Model
Battery Type 12V Lead Acid 12V Lead Acid 12 V/7 Ah 12 V/9 Ah N/A
Numbers (10+10) PCS (16+16) PCS (16+16) pcs x 2 strings
Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacity
Charging Current (max.) 2A (Adjustable) 1A ~ 12A 1A ~ 16 A (Adjustable)
Charging Voltage +/-13.65V*N (N = 10) +/-13.65V*N (N = 16~20) +/-218 VDC ± 10%
Long-run
Model
Battery Type Depending on the applications
Numbers 20PCS 32PCS +/-16 pcs ~ +/- 20 pcs (Adjustable)
Charging Current (max.) 1A/2A/3A/4A/5A/6A/7A/8A/9A/10A/11A/12A (Adjustable)12A maximum 1A ~ 12A (Adjustable) 1A~16 A (Adjustable) 2A~24 A (Adjustable) 2A~32A(Adjustable)
Charging Voltage +/-136.5VDC±10% +/-13.65V x N (N=16~20)
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
PHYSICAL
Standard
Model
Dimension,DxWxH (mm) 630 x 250 x 826 815 x 300 x 1000 N/A
Net Weight (kgs) 103 139 225 250
Long-run
Model
Dimension,DxWxH (mm) 630 x 250 x 826 815 x 300 x 1000 790 x 360 x 1010
Net Weight (kgs) 36 43 60 67 108 113
ENVIRONMENT
Operation Temperature 0-40°C
Operation Humidity < 95% and non-condensing
Altitude** 0 ~ 1500m at full load
Noise Level Less than 60 dB@1 Meter Less than 65 dB @1 Meter Less than 63 dB @1 Meter Less than 65 dB @1 Meter
MANAGEMENT
Smart RS-232 / USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser

note: (L* mark means Long backup model)

Get the latest price? We'll respond as soon as possible(within 12 hours)
close left right