Double Conversion Online Low Frequency UPS Power Supply for Hospital

Model: Double-conversion Low Frequency Online UPS Capacity: 10kva~300kva Wave Type: Pure Sine Wave Brand: ROYCE ENERGY or OEM

The Isolated Gate Bipolar Transistors (IGBT) in the GP33 series online double conversion Low Frequency UPS power supply provide outstanding sine wave output conversion from high frequency PWM inverters. The series can be used in small and medium-sized data centers, network management centers, and computer rooms for businesses. It can address issues such as sudden drops in voltage or concussion damping, high-voltage pulses, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuations. It also ensures that users will always have access to a safe and dependable power source.

Features of Double Conversion Online Low Frequency UPS Power Supply

⚫  Highly effective DSP chips
⚫  Magnificent electrical asset
⚫  Stylish and top-notch hardware
⚫  N+1 parallel redundancy (compatible with parallel mode battery share)
⚫  Frontal-board upkeep and operation
⚫  Line input with dual channels
⚫  Online observation
⚫  Sensible control over battery discharge and charging
⚫  Adaptable battery configuration
⚫  Adaptable setup that can modify as needed
⚫  Integrated lightning protection system

Specifications of Double Conversion Online Low Frequency UPS Power Supply

MODEL GP33-10-20KS GP33-30-40KS GP33-60-80KS GP33-100-120KS GP33-160-200KS GP33-250-300KS
Capacity 10/15/20Kva 30/40Kva 60/80Kva 100/120Kva 160/200Kva 250/300Kva
UPS(L*W*D) 402x660x880 412x813x1121 505x1060x1321 555x1060x1421 1043x1160x1748 1600x1182x1962
Pack (L*W*D) 505x800x1030 515x926x1270 603x1190x1486 653x1190x1586 1303x1180x2076 1760x1301x2168
UPS weight (kg) 153/168/194 223/256 382/434 535/580 1120/1320 1540/1745
Temperature 0~40
Humidity 0~95% non condensate
Noise <60dB @1.5m from surface of unit
Altitude 1000m(height rises every 100m, power decreases 1%, maximum height is 4000m)
Efficiency Power saving mode>98%, Inverter>92%, AC-AC91%
Transference 0ms
Technology True double-conversion online technology conversion performed by IGBT
Input
Voltage 3*220/380 vac ± 25%
Frequency 50Hz ± 15%
Conductors Three Phases + N + E
Output
Voltage (selectable) 3*220/380 vac ± 1%
Frequency 50Hz ± 0.1%
Waveform Pure sine wave generated by high frequency PWM inverter
Harmonic Distortion <2% Linear Load / <5% Nonlinear Load
Crest Factor 3:1
Power Factor 0.8 or 0.9
Overload Recuperation Automatic transfer to normal
Voltage Regulation Load balance: ± 1%
Overload Capacity 125% for 12 minutes/ 150% for 1 minute
Conductors Three Phases + N + E
Battery
Type Maintenance-free sealed lead-acid battery, 12V*32 batteries
Full load autonomy 3 to 15 minutes, extended-range capacity
Typical recharge time 4~8 hours, 90%
Battery behavior Autotest, Transfer Point Adjustable battery and alarm setting
Battery protection Fuse protection, battery switch, temperature compensation, regular inspection, software protection, overvoltage tripping.
Rectification Software protection, input switch, over current protection, temperature protection.
Protection
Hardware protections Breaker for input, output, battery and bypass. Fast acting fuses in DC, fans, redundant power supplies, temperature sensors, on-o switch and audible alarms.
Bypass Static solid state, automatic and manual operation without interruption for maintenance. External Bypass(optional)
Emergency switch Remote and/or local EPO
Supervisory control and communication
Frontal panel Interactive LCD display(Touchscreen)
Alarms Audible and visual alarm for abnormal conditions
Communications RS232, SNMP-RJ45, GPRS (RS232 & RJ45 standard, the other is optional)